Multiple Fixture Wiring

Printer Friendly Version of Article

WHILE EXTREME CARE HAS BEEN IMPLEMENTED IN THE PREPARATION OF THIS SELF-HELP DOCUMENT, THE AUTHOR AND/OR PROVIDERS OF THIS DOCUMENT ASSUMES NO RESPONSIBILITY FOR ERRORS OR OMISSIONS, NOR IS ANY LIABILITY ASSUMED FROM THE USE OF THE INFORMATION, CONTAINED IN THIS DOCUMENT, BY THE AUTHOR and / OR PROVIDER.

Read the legal disclaimer page - click the legal link in the menu above

Adding additional light fixtures to an existing switch / light circuit?

DO NOT WIRE IN SERIES...

Series Wrong Way

This is an absolute no no, never wire light fixtures in this manner.


Some Christmas tree light sets may be wired in this fashion, but never use this style of wiring for home light fixtures. First you would have dim lighting as voltage drops would occur across each lighting fixture, 2nd as in the old style Christmas tree lighting one light that burns out all go will go out, 3rd it would be a major code violation as well as a safety issue.
 

The correct way to wire multiple fixtures controlled by the same switch circuit...

Correct way to wire multiple fixtures

Starting with the actual wires connected to the 1st fixture, join the onward cable by insulated wire nuts to the next fixture as depicted in the picture above. The black wire is the switched ungrounded conductor (hot) and gets connected to the ungrounded conductor [hot] of the fixture itself (if screw connectors it would connect to the brass color screw); the white wire is the grounded conductor (neutral) and connects at each fixture to the grounded conductor [neutral] (if screw connectors it would connect to the silver color screw).

There is also an equipment grounding conductor not shown in the picture, that would be the bare wire in the wire cable (green wires are also equipment grounding conductors), all equipment grounding conductors are joined together at each fixture box as well as any grounding screw or grounding wire at the fixture itself, and to the electrical box itself if metallic or has a metal strip within the box with grounding screws.

If you are using a dimmer make certain that the max current / wattage rating of the dimmer exceeds the combine current / wattage requirements of all fixtures on that same switch circuit. Also regular dimmers are only to be used with incandescent lighting.

Written: Jan. 15, 2012
Revised: June 29, 2013
Proof Read / Released: July 10, 2013
By: Donald Kerr

QUICK MENU 

Home (Wiring Done Right)
2011 NEC New Rule 'Switch Connections'
3 Way Switch
4 Way Switch
Accessory Buildings
Adding Outlet
Aluminium Wiring
Arc Circuit Protection
Backup Generators / Transfer Switches
Basic Switch
Box Fill Calculations
Breaker Circuit Types
Conduit Fill
Convert Pull String to Wall Switch
Definitions
Dryer Outlet
Electrical Box Types
Electrical Dangers
Electrical Safety
Electricity, What is It?
Fan / Light Combo
Generation / Distribution Grid
GFI Outlets
Home Electrical Design
Main Electrical Panel
Multiple Fixture Wiring
Old Home / Wiring
Outlet, Half Switched
Range Outlet
Series Switches
Split Circuit Outlet
Sub Panel
Switch Outlet Types
Testing Equipment
Tools, Basic Tools
Trouble Shooting
Wire Cable Types
Wire Connections
Wire Routing Basics
Work Shop Wiring
World, Electricity around the

Copyright 2014 +
All Rights Reserved
Donald Kerr / Wiring Done Right / MegaWeb
http://wiringdoneright.megaweb.xyz